The Lombard Effect Observed in Speech Produced by Cochlear Implant Users in Noisy Environments: A Naturalistic Study

DSpace/Manakin Repository

The Lombard Effect Observed in Speech Produced by Cochlear Implant Users in Noisy Environments: A Naturalistic Study

Show full item record

Title: The Lombard Effect Observed in Speech Produced by Cochlear Implant Users in Noisy Environments: A Naturalistic Study
Author(s):
Lee, J.;
Ali, H.;
Ziaei, A.;
Tobey, Emily A.;
Hansen, John H. L.
Date Created: 2017-04-20
Item Type: article
Keywords: Show Keywords
Description: Full text access from this site is available only to current UTD affiliates.
Abstract: The Lombard effect is an involuntary response speakers experience in the presence of noise during voice communication. This phenomenon is known to cause changes in speech production such as an increase in intensity, pitch structure, formant characteristics, etc., for enhanced audibility in noisy environments. Although well studied for normal hearing listeners, the Lombard effect has received little, if any, attention in the field of cochlear implants (CIs). The objective of this study is to analyze speech production of CI users who are postlingually deafened adults with respect to environmental context. A total of six adult CI users were recruited to produce spontaneous speech in various realistic environments. Acoustic-phonetic analysis was then carried out to characterize their speech production in these environments. The Lombard effect was observed in the speech production of all CI users who participated in this study in adverse listening environments. The results indicate that both suprasegmental (e.g., F0, glottal spectral tilt and vocal intensity) and segmental (e.g., F1 for /i/ and /u/) features were altered in such environments. The analysis from this study suggests that modification of speech production of CI users under the Lombard effect may contribute to some degree an intelligible communication in adverse noisy environments. © 2017 Acoustical Society of America.
Publisher: Acoustical Society of America
ISSN: 0001-4966
Link to Related Resource: http://dx.doi.org/10.1121/1.4979927
Persistent Link: http://hdl.handle.net/10735.1/5983
Bibliographic Citation: Lee, J., H. Ali, A. Ziaei, E. A. Tobey, et al. 2017. "The Lombard effect observed in speech produced by cochlear implant users in noisy environments: A naturalistic study." Journal of the Acoustical Society of America 141(4): 2788-2799.
Terms of Use: ©2017 Acoustical Society of America
Sponsors: National Institutes of Health (National Institute of Deafness and other Communication Disorders (NIDCD)) grant no. R01 DC010494-01A

Files in this item

Files Size Format View
JECS-3626-LINK-8154.66.pdf 254.4Kb PDF View/Open Link to Article

This item appears in the following Collection(s)


Show full item record